Back

Journal of the Mechanical Behavior of Biomedical Materials

Elsevier BV

Preprints posted in the last 7 days, ranked by how well they match Journal of the Mechanical Behavior of Biomedical Materials's content profile, based on 24 papers previously published here. The average preprint has a 0.02% match score for this journal, so anything above that is already an above-average fit.

1
A Tunable Flat-Jet Hydro-Debridement Device: Clinical Feasibility for Soft Tissue Wound Management

DATTA, A.; Majumder, R.; Biswas, I.; Ganguly, R.; Santra, A. K.; Sarkar, S.; Gumta, M. K.; Sarkar, S.

2026-09-04 surgery 10.64898/2026.09.01.26361120 medRxiv
Top 0.1%
2.6%
Show abstract

Background: Chronic wounds, ulcers, and lacerations require staged debridement and irrigation to promote healing. However, conventional techniques of debridement, such as surgical, chemical, or autolytic, struggle to fully remove residual necrotic tissue, slough, and unhealthy granulation from wound sites, especially when lodged within wound clefts and cavities, and in wounds with exposed structures. This promotes polymicrobial biofilms, delays wound closure, and causes significant discomfort with increased morbidity. Objective: To demonstrate the feasibility of using an indigenously developed tunable flat-jet hydro-debridement device (presently termed as CleanseJet), a frugal wound debridement system designed for deployment in resource-constrained clinical settings. Methods: An open-label, interventional, single-centre, parallel-group pilot randomized controlled trial was conducted to clinically evaluate an indigenously developed tunable flat-jet hydro-debridement device in patients with wounds of varied aetiology. The device provided adjustable spray impact force and coverage area tailored to wound characteristics. Outcomes were compared with a control group receiving standard wound care alone, with time to complete granulation serving as the primary healing endpoint. Outcomes were compared with a control cohort receiving standard of care alone. Results: The removal of loose devitalized tissue, slough, and biofilms from the wound bed improved the healing, which were monitored using the SINBAD scoring system. No adverse events were reported, supporting the feasibility and safety of CleanseJet. Conclusion: While commercial hydro-debridement systems are effective, they are often costly, rely on disposable components, and require specialized training. In contrast, CleanseJet provides a low-cost, easy-to-use alternative that can be operated with minimal training, making it suitable for broader clinical use without observed adverse effects.

2
Feasibility study of gait analysis using a new Wearable Force Plate

Sanz Morere, C. B.; Garrido-Lopez, G.; Hayase, M.; Rueda, J.; An, Q.; Shimoda, S.; Moreno, J. C.; Navarro, E.

2026-09-02 rehabilitation medicine and physical therapy 10.64898/2026.08.30.26361786 medRxiv
Top 0.2%
2.1%
Show abstract

Static force plates (FP) are the gold standard for measuring ground reaction forces (GRF) and computing joint moments through inverse dynamics in gait analysis. However, they are restricted to controlled environments, and the number of steps analyzed is limited by the plates embedded in the floor. To address these limitations, portable solutions such as sensorized insoles, socks, or shoes have emerged. Yet, creating wearable systems capable of measuring three-dimensional GRF in real-world conditions remains challenging. Current sensorized shoes often incorporate thick sensors (up to 2 cm), reducing usability and limiting their application in pathological populations or dynamic tasks like running. This study evaluates the usability of ShokacShoes, a novel sensorized shoe integrating three thin, three-dimensional force sensors, and explores its potential as a Wearable Force Plate (WFP). Eight healthy participants performed slow, natural, and fast walking using two insole configurations. Force and temporal metrics were derived from WFP and FP data. Results indicate that WFP enables accurate step segmentation and detects significant effects of speed and insole type on temporal and force metrics, confirming its reliability under different walking conditions. Comparisons with FP revealed differences in force metrics and signal morphology, though temporal parameters remained consistent. These results are likely due to sensor quantity and positioning. Thereby, ShokacShoes represent a valid solution capable of measuring three-dimensional forces within commercial footwear. Future work will focus on validating the applicability of a new version of ShokacShoes against gold-standard FP in a comprehensive validation study involving diverse real-world scenarios and pathological conditions.

3
What Matters Most: A Multi-Stakeholder Study of Outcome Domains in Lower-Limb Prosthesis Use

Ahmed, M. E.; Karlsson-Brown, S.; Koufaki, P.; Ahmadi, M.; Mico-Amigo, E. M.

2026-09-03 rehabilitation medicine and physical therapy 10.64898/2026.08.31.26361544 medRxiv
Top 0.3%
1.0%
Show abstract

Purpose: Lower-limb prosthesis use involves interacting physical, psychosocial, and device-related outcomes that may not be fully captured by conventional clinical assessment. This study aimed to develop and evaluate a stakeholder-informed framework of outcome domains relevant to meaningful everyday prosthesis use. Materials and Methods: A mixed-methods participatory design comprised a structured synthesis of selected clinically relevant content from five established patient-reported outcome measures; semi-structured interviews and importance and actionability ratings with 18 contributors (12 prosthesis users, four clinicians, and two industrial partners); and integration of the synthesis, qualitative, and rating findings. Interview records were analysed using reflexive thematic analysis, and ratings were analysed descriptively. Results: The resulting framework comprised four interrelated domains: Mobility, Physical Function, Psychosocial Wellbeing, and Prosthesis Experience. Mobility showed the clearest convergence across stakeholder perspectives. Prosthesis users showed the largest importance actionability gap for Prosthesis Experience (4.5 vs 3.0), whereas clinicians showed the largest gap for Psychosocial Wellbeing (5.0 vs 3.0). Interviews highlighted day-to-day variability in prosthesis use and the influence of confidence, fatigue, comfort, environmental conditions, social context, and device usability. Conclusions: Meaningful outcome assessment in prosthetic rehabilitation should extend beyond mobility alone to consider physical function, psychosocial wellbeing, and prosthesis experience within everyday contexts. The proposed framework provides a stakeholder-informed foundation for multidimensional outcome assessment in prosthetic rehabilitation.

4
Mechanical elements related to the development of patellofemoral pain syndrome, pain intensity, and functional disability: A cross-sectional study

Yaghoubi, N.; Eghbali, M.; Soleimanifar, M.; Hashemirad, F.; Arab, A.

2026-08-31 rehabilitation medicine and physical therapy 10.64898/2026.08.26.26361453 medRxiv
Top 0.4%
0.8%
Show abstract

Background and purpose: Patellofemoral pain syndrome (PFPS) is a multifaceted condition where proximal, local, and distal factors may contribute to symptoms and limitations. How these factors collectively contribute to PFPS remains poorly understood. Therefore, this study compared proximal, local, and distal mechanical characteristics between individuals with and without PFPS and investigated their association with pain intensity and functional disability. Methods: Eighty participants were included: 40 individuals with unilateral or bilateral PFPS, 40 healthy controls. Isometric muscle strength of hip, trunk, and ankle was assessed using a handheld dynamometer. Joint alignment (Q-angle, rearfoot angle, pelvic tilt) and muscle flexibility (iliotibial band, hamstrings, quadriceps, gastrocnemius, and soleus) were measured using standard clinical techniques. Pain severity was assessed using a visual analog scale (VAS), and functional disability was evaluated using the Kujala score. Results: Individuals with PFPS showed reduced iliotibial band flexibility, decreased hamstring and soleus length, lower hip abductor strength, and greater anterior and lateral pelvic tilt (all p < 0.02). Multivariate analysis identified reduced iliotibial band flexibility (OR = 7.48) and greater anterior pelvic tilt (OR = 11.75) as independent associates of PFPS. Anterior pelvic tilt predicted pain severity, while anterior trunk muscle strength and Q-angle predicted disability. Discussion: Reduced iliotibial band flexibility and increased anterior pelvic tilt were independently associated with PFPS, while anterior pelvic tilt predicted pain severity and anterior trunk muscle strength and Q-angle predicted functional disability. Clinical assessment and rehabilitation of PFPS should therefore extend beyond the knee to include iliotibial band flexibility, pelvic alignment, and trunk muscle strength.

5
Spatial Geometry and Prevalence of Tunneling and Undermining in Pressure Ulcers

Frade, S.; Tunyiswa, Z.; Shin, M.; Dirks, R.

2026-09-01 dermatology 10.64898/2026.08.28.26361615 medRxiv
Top 0.4%
0.6%
Show abstract

Background: Pressure ulcers often develop complex three-dimensional morphologies that extend beyond the visible wound surface. Subsurface extensions such as tunneling and undermining create hidden cavities that complicate clinical assessment and wound management. Despite their clinical relevance, the prevalence and spatial characteristics of these subsurface wound morphologies have not been well characterized at scale. Methods: We performed a registry-based analysis using data from the LIFT-OFF Pressure Ulcer Registry, which captures longitudinal clinical documentation of pressure ulcers treated in routine care. The registry included approximately 18,000 patients with 32,000 documented pressure ulcers. Spatial characteristics of tunneling and undermining were analyzed using measurements recorded during routine wound assessments, including tract length, direction, and circumferential extent. Directional and circumferential distributions of subsurface defects were examined to characterize wound geometry. Results: Tunneling was present in 764 of 14,700 full-thickness pressure ulcers (5.2%), whereas undermining occurred in 2,293 wounds (15.6%). Tunneling tracts were typically short and exhibited directional clustering relative to the wound bed. In contrast, undermining demonstrated broader circumferential distributions and frequently involved larger subsurface separations beneath the wound margin. Both morphologies demonstrated distinct spatial patterns across anatomical locations and wound stages. Conclusion: Tunneling and undermining are common subsurface features of pressure ulcers and exhibit distinct spatial geometries. Whereas tunneling manifests as directional tract-like extensions, undermining more frequently produces circumferential tissue separation beneath wound margins. Improved characterization of subsurface wound architecture may enhance assessment of wound complexity and provide information not captured by surface measurements alone. Future studies should evaluate whether these features contribute to wound severity assessment, prognosis, and risk stratification.

6
Influence of trunk posture on spinal loading and paraspinal muscle forces in adolescent idiopathic scoliosis: a subject-specific musculoskeletal modelling study

Bhattacharya, R.; Garg, B.; Malhotra, R.; Ghosh, R.; Chawla, A.; Mukherjee, K.

2026-09-01 bioengineering 10.64898/2026.08.28.747718 medRxiv
Top 0.4%
0.6%
Show abstract

Adolescent idiopathic scoliosis (AIS) alters spinal geometry and may influence the biomechanical response of the spine during functional postures. However, posture-dependent changes in spinal loading and paraspinal muscle forces in AIS remain poorly understood. This study investigated the effects of trunk posture on intervertebral loading and paraspinal muscle forces using a subject-specific musculoskeletal model of an adolescent with AIS. The spinal deformity was reconstructed from biplanar radiographs and incorporated into a full-body musculoskeletal model. Flexion, extension, lateral bending, and axial rotation were simulated at three incremental magnitudes, with motion distributed across the thoracolumbar spine. Intervertebral compressive and lateral forces around the curve apex and forces in the erector spinae (ES) and multifidus (MF) muscles were evaluated. Trunk flexion produced the greatest compressive loading, reaching 337 N at the curve apex and 372 N two levels below the apex at 30{degrees} flexion. Lateral bending produced pronounced direction-dependent loading: concave-side bending increased lateral forces, whereas convex-side bending increased compressive forces. Axial rotation produced similar but smaller direction-dependent changes. Paraspinal muscle forces were consistently asymmetric, with concave-side dominance of the ES and convex-side dominance of the MF. Flexion and convex-sided movements generally produced greater muscle imbalance, while increasing posture magnitude amplified spinal loading and muscle forces. These findings demonstrate that trunk posture, movement direction, and magnitude substantially influence the biomechanical environment of the scoliotic spine and should be considered when evaluating spinal mechanics in AIS.

7
3D ultrasound fascicle tractography for objective muscle architecture analysis.

Tecchio, P.; Schlaffke, L.; Bolsterlee, B.; Hahn, D.; Raiteri, B. J.

2026-09-01 bioengineering 10.64898/2026.08.31.746736 medRxiv
Top 0.6%
0.5%
Show abstract

Muscle architecture shapes muscle function and changes with age, growth, training and disease, yet quantifying three-dimensional (3D) muscle architecture in vivo remains challenging. We introduce a hybrid fascicle tractography approach for freehand 3D ultrasound data that accurately reconstructs 3D muscle fascicles with respect to an objective, anatomically relevant coordinate system defined by the muscle's central aponeurosis. The hybrid approach combines Hessian-based fascicle detection with wavelet-based refinement to generate volumetric fascicle orientations. In a synthetic dataset with known ground truth, fascicle orientations and lengths were estimated with errors of [&le;]2{degrees} and ~1.5%, respectively. In vivo, the approach detected physiologically plausible fascicle lengthening in the human tibialis anterior following a passive plantar flexion rotation, whereas diffusion tensor imaging of the same muscle did not. The proposed method enables anatomically relevant, objective and non-invasive quantification of 3D muscle architecture in vivo, providing a practical framework for applications in clinical and applied muscle physiology.

8
Shape Analysis of Coronary Flow Waveforms using Singular Value Decomposition

Sturgess, V. E.; Schenk, N. A.; Ziegele, J. W.; Essajee, S. I.; Tune, J. D.; Rajapakse, I.; Figueroa, C. A.; Beard, D. A.

2026-08-31 physiology 10.64898/2026.08.26.743980 medRxiv
Top 0.7%
0.3%
Show abstract

Coronary flow waveforms have a distinct diastolic-dominant shape with periods of low or retrograde flow during systole. While the general waveform shape has been attributed to complex interactions between cardiac and vascular mechanics, there is limited research into the variability in coronary flow waveforms and what this variability may reveal about cardiac function. This work presents a shape analysis of left anterior descending artery (LAD) flow waveforms using Fourier transforms and Singular Value Decomposition (SVD) performed on baseline data collected from 32 pigs. Pigs included in the study reflect two breeds (Ossabaw and Yorkshire) and three different experimental conditions (lean-control, lean-paced, and obese-paced). Fourier transforms were used to decompose the waveforms into 15 harmonics for each pig. An SVD analysis is then used to extract temporal patterns of the waveforms. Correlations between pig-specific coefficients for the SVD modes and clinical metrics were used to investigate physiological explanations of LAD waveform variability. Temporal LAD flow patterns of the second SVD mode are significantly correlated with heart rate. The third SVD mode significantly correlates with mean blood pressure and maximum hyperemic flow. Furthermore, the fourth SVD mode is weakly correlated with left-ventricular end diastolic pressure and endocardial-epicardial flow ratios. This work demonstrates that LAD flow waveforms can be broken down into temporal patterns that correlate with physiological features. Furthermore, this shape-analysis method allows for waveform reconstruction and simplifies visualization of the temporal patterns identified using SVD, an advantage over existing methods that focus on characterizing flow waveforms by points of interest.

9
Integrating mouthguard kinematics, finite element brain strain, and plasma biomarkers to explore brain injury thresholds in collision sport

Hickey, J. W.; Chan, E. Y. K.; Evans, L. J.; O'Brien, W. T.; Xie, B.; Roberts, S. S. H.; Butler, S. E.; Ernst, J.; Zhou, W. J. Q.; Zimmerman, K. A.; Spitz, G.; Parker, T. D.; O'Brien, T. J.; Shultz, S. R.; Sharp, D. J.; Ghajari, M.; McDonald, S. J.

2026-08-31 sports medicine 10.64898/2026.08.26.26360869 medRxiv
Top 0.7%
0.3%
Show abstract

Purpose: Identifying head impacts linked to brain injury in sport remains challenging. Instrumented mouthguards quantify head-impact kinematics, and finite element (FE) modelling can transform these data into brain strain estimates, which may better reflect injury risk than kinematics alone. Here, we examined associations between mouthguard-measured kinematics, FE-derived strain, and plasma brain injury biomarker GFAP following head impacts. Methods: We analysed 41 video-verified impacts from male Australian football players, including 22 assessed for concussion (17 diagnosed) and 19 unassessed. Instrumented mouthguards recorded peak linear acceleration (PLA), peak rotational acceleration, and peak rotational velocity (PRV). Brain strain was estimated using the Imperial College FE brain model, and plasma GFAP was quantified using Simoa. Biomechanical-GFAP associations were examined using Spearman correlations and segmented regression. Results: For impacts overall, plasma GFAP was moderately correlated with PLA ({rho}=0.46, 95% CI: 0.20-0.66), PRV ({rho}=0.53, 95% CI: 0.20-0.78), and strain ({rho}=0.60, 95% CI: 0.32-0.80). Associations were stronger within concussion cases for strain ({rho}=0.86, 95% CI: 0.58-0.97) and PRV ({rho}=0.64, 95% CI: 0.15-0.93). Piecewise regression identified strain levels above which strain-GFAP relationships steepened across the whole-brain and brainstem. In concussion cases, supra-threshold brainstem strain was associated with greater symptoms. Conclusion: Finite element brain strain may better predict brain injury risk following a sport-related head impact than peak acceleration metrics. Stronger associations with plasma GFAP, particularly among concussion cases, and evidence of a biomechanical threshold, support the use of biomarker-informed strain measures in future risk modelling and the development of brain injury screening thresholds.

10
Multilayered extracellular matrix derived scaffolds direct progenitor cell differentiation in vitro and osteochondral-tissue formation in vivo.

Gonnella, G.; Strong, O.; Sularea, V. M.; Soares Kronemberger, G.; Karam, A. S.; Kelly, D.

2026-08-31 bioengineering 10.64898/2026.08.28.747815 medRxiv
Top 0.8%
0.3%
Show abstract

Osteochondral repair requires restoration of zonally organised articular cartilage and subchondral bone, yet translatable implants rarely reproduce this spatial complexity. Here, we developed an off-the-shelf, cell-free multilayer scaffold comprising a superficial 2% (w/v) articular cartilage extracellular matrix (AC-ECM) phase, an intermediate 5% AC-ECM phase and a basal 6% bone ECM (BN-ECM) phase. The scaffold formed continuous interfaces, displayed regionally distinct pore sizes and resisted permanent deformation during cyclic compression. In vitro, constructs seeded with caprine mesenchymal stromal and articular cartilage progenitor cells supported cell expansion and the accumulation of sulfated glycosaminoglycan- and collagen-rich matrix, with regional differences in collagen I, II and X deposition. Following eight weeks of subcutaneous implantation, cell-seeded scaffolds contained more collagenous matrix than unseeded controls, while vascularisation preferentially localised to the BN-ECM phase. The scaffold was then evaluated against empty defects in a caprine osteochondral model for six months. Scaffold treatment significantly improved macroscopic and histological repair, increased chondral tissue fill (~60% versus ~40%), limited cartilage-like tissue extension into the subchondral region and generated a more native-like superficial collagen organisation. Repair tissue further exhibited greater collagen II immunoreactivity, increased ACAN and COL2A1 expression and reduced COL1A2 expression relative to empty defects, although deeper bone repair was not significantly improved. These findings demonstrate that tissue-specific ECM layering can spatially guide endogenous repair and substantially improve cartilage restoration without exogenous cells or growth factors in a clinically relevant large-animal model, while identifying subchondral bone regeneration as the remaining design challenge for complete osteochondral repair.

11
Arm Angle Moderates the Association Between Fastball Usage and Elbow/Forearm Injury in MLB Pitchers

Richards, C.; La Salle, D. T.; Vila Dieguez, O.; Ward, S. R.

2026-08-31 sports medicine 10.64898/2026.08.29.26361727 medRxiv
Top 0.9%
0.2%
Show abstract

Background: Newly available arm angle data offers a new dimension to understand rising rates of arm injury in MLB pitchers. Purpose: To evaluate the relationship between arm angle, pitch characteristics, and elbow and forearm injury in MLB pitchers.<br><br> Study Design: Retrospective cohort study; Level of evidence, 3 Methods: Statcast data from 2020 to 2025 and MLB injured list (IL) data were used to evaluate arm angle and pitch characteristics in relation to elbow and forearm injuries. Results are presented with and without requirements on prior season workload and for same-season and next-season injury incidence. A generalized additive model (GAM) was used to capture non-linear dependence and interactions between selected features and injury incidence to the elbow or forearm. Average marginal effect (AME) odds ratios are reported for main effect terms. Results: N = 3,812 pitcher-seasons were included. 29% pitchers who underwent UCLR did so in the same season as a forearm injury (tmean=44, tmedian=27 days to surgery). Arm angle, fastball usage, and their interaction were the three most predictive features. Arm angle was positively related to incidence of injury (ORmeanAME=1.014), fastball usage was inversely related to incidence of injury (ORmeanAME=0.243), and arm angle moderated the effect fastball usage at high arm angle, where increased usage was no longer protective. Slider velocity (ORmeanAME=1.072), spin rate (ORmeanAME=1.001), and usage (ORmeanAME=2.039) also significantly predicted injury risk. Fastball velocity was not significant in any fit, with ORmeanAME=0.999 across all fits. Fit-level Nagelkerke R2 values ranged from .019 to .052. Conclusion: Fastball usage and arm angle, not velocity, predicted elbow and forearm injury risk among MLB pitchers, and arm angle was the single most predictive feature. The heterogeneity of risk factors as a function of arm angle, and the novelty of MLB arm angle data, may explain why fastball usage has been previously underexplored as a risk factor. Keywords: baseball; arm angle; fastball velocity; fastball usage; spin rate; UCL; ulnar collateral ligament; elbow injury; forearm injury; Statcast

12
Concordance Between a Temple-Worn Optical Wearable and Transcranial Doppler During Exercise and Postural Transitions in Healthy Adults

Kumar, A.; van Rosmalen, L.; Gupta, A.; Sharma, S. K.; Gupta, R. C.; Panda, S.; Jain Gupta, N.

2026-09-04 cardiovascular medicine 10.64898/2026.09.02.26362022 medRxiv
Top 0.9%
0.2%
Show abstract

Cerebral hemodynamics are difficult to monitor continuously outside the laboratory. Optical head-worn wearables have been proposed for tracking cerebral blood-flow signals, but they require comparison with an established cerebrovascular reference before they can be interpreted. We evaluated a temple-worn optical wearable, Temple, that outputs a proprietary, dimensionless Brain Flow index, intended as a proxy for relative changes in cerebral hemodynamics, against transcranial Doppler (TCD) ultrasound, which measures blood-flow velocity in the middle cerebral artery (MCAv). Twenty-three healthy adults completed two physiological challenges that elicit distinct and acute cerebral hemodynamic responses: a cycle-ergometer exercise protocol and a stand-to-supine postural transition protocol. Twenty participants were analyzed per protocol. The Brain Flow index tracked MCAv in both protocols, with significant within-subject temporal correlations (median Pearson r = 0.795 and 0.799 for exercise and postural transition; p < 0.001) and directionally concordant, statistically significant transition responses for both increases and decreases in flow. Bland-Altman analysis of the normalized transition responses showed small mean biases between the two devices, consistent with similar relative response shapes. Because both signals were standardized within session before this comparison, it addresses the shape of the relative change rather than agreement in absolute units. The Brain Flow index reproduced the direction and time course of MCAv under both perturbations, including the postural transition, where heart rate moved in the opposite direction. Further studies using complementary modalities and additional cerebrovascular reactivity challenges are required to establish clinical use cases and cerebral specificity of the Brain Flow index.

13
The Role Of Liquid Crystal Ordering In The Structural Organization Of DNA In Bacteria.

Krupyanskii, Y. F.; Kovalenko, V.; Loiko, N.; Generalova, A.; Tereshkin, E.; Tereshkina, K.; Sokolova, O.; Peters, G.

2026-09-01 biophysics 10.64898/2026.08.31.748243 medRxiv
Top 1%
0.2%
Show abstract

This paper presents and critically reviews the results of original and some literature based experimental studies conducted by the authors last years on the structural organization of DNA in dormant (starvation stress), anabiotic dormant (4 HR treatment) E. coli cells, as well as the K12 {Delta}dps strain, which lacks the Dps protein (Dps null E. coli). The experimental data includes small-angle synchrotron radiation diffraction (SAXS) and transmission electron microscopy (TEM) data. Synchrotron radiation diffraction experiments on K12{Delta}dps cells allowed us to conclude that peaks at 44.3, 22.1, and 14.8 angstrom resolutions are associated exclusively with ordered DNA organization. Peaks at 44.3, 22.1, and 14.8 angstrom resolutions are also observed for samples of dormant (starvation stress) cells and anabiotically dormant cells. Therefore, this ordered DNA organization also applies to samples of dormant and anabiotically dormant cells. A model is proposed that considers the ordered DNA organization in the cell as a cholesteric liquid crystal. The powder diffraction pattern calculated based on this model is compared with experimental small angle X ray scattering (SAXS) data obtained on Dps-null cell samples. The model completely reproduces the key features of the experimental diffraction pattern from Dps-null cell samples. Accordingly, the cholesteric liquid crystal model corresponds to DNA packaging in dormant and anabiotically dormant cells. Cholesteric liquid crystal ordering should be further considered in all models of cellular DNA packaging. To address the question of which structural organization of DNA predominates in the cell: the cholesteric liquid crystal or nanocrystalline or whether they coexist and fully manifest themselves under different external conditions, it is necessary to utilize the latest methodological advances in structural analysis.

14
A fibril-inducing support-bath enables embedded 3D printing of aligned collagen-rich constructs

Gonnella, G.; Milazzo, R.; Gibney, R.; Kelly, D.

2026-08-31 bioengineering 10.64898/2026.08.30.748057 medRxiv
Top 1%
0.2%
Show abstract

Embedded extrusion printing can process collagen-rich bioinks, but their low viscosity and slow fibrillogenesis compromise print fidelity and post-deposition stability. Here, we developed a collagen fibril-inducing support bath (FIB) that combines mechanical support for embedded printing with biochemical induction of collagen assembly. Microfibrillated or nanofibrillated cellulose was incorporated into a fibril-inducing buffer, and formulations were screened at 37 degrees Celsius for rheological behaviour and optical transparency. The selected FIB was evaluated by printing 1% and 5% (w/v) articular cartilage-derived extracellular matrix (ECM) inks at 10-20 mm/s and compared with a cellulose-only control bath. FIB exhibited yield-stress, shear-thinning and rapid recovery behaviour that supported reproducible filament deposition. Unlike the control bath, FIB enabled intact construct retrieval following stabilisation and promoted the formation of fibrillar collagen within the printed strands. Scanning electron microscopy revealed D-banded collagen fibrils preferentially oriented along the deposition direction, with dominant orientation peaks within +/- 10-15 degrees. The platform supported the fabrication of 15 x 15 x 1.5 mm sheets and 6 x 6 x 6 mm scaffolds whose macroscopic dimensions were retained after processing. Constructs produced from 5% ECM inks exhibited approximately fourfold higher ramp and relaxation moduli than those produced from 1% ECM inks. Extracts from both formulations caused no detectable reduction in cell metabolic activity after 24 h or 72 h. Mesenchymal stem/stromal cells (MSCs) seeded onto printed sheets became markedly elongated and aligned by day 3, with approximately 80% of cells having an aspect ratio exceeding 1.5, significantly greater than cells seeded onto casted ECM controls, with a mean deviation of ~9 degrees from the filament print direction. These findings establish FIB as a bioactive support bath that couples embedded printability with collagen fibrillogenesis, enabling recoverable collagen-rich constructs with aligned fibrillar architecture that directs early cellular organisation.

15
Quantifying sprint force-velocity elasticity: implications for individualized training decisions

Li, Z.; Yan, J.; Zhang, X.; Chen, Z.; Li, Q.; Jimenez-Reyes, P.; Janicijevic, D.; garcia-ramos, A.

2026-09-01 biophysics 10.64898/2026.08.29.748040 medRxiv
Top 1%
0.1%
Show abstract

This study aimed to (1) develop an elasticity framework for the sprint force-velocity (F-V) relationship and (2) examine how maximal force (F_{0}), maximal velocity (v_{0}), and sprint distance modulate the four derived elasticity metrics, and (3) explore these elasticity metrics' interrelation. After modelling the F-V relationship differential equation, four elasticity metrics were defined as force elasticity (F_{e}), the elasticity of sprint time to F_{0}; velocity elasticity (v_{e}), the elasticity of sprint time to v_{0}; the force-velocity elasticity norm {(\mathrm{F}-\mathrm{V}}_{\mathrm{EN}}=\sqrt{F_{e}^{2}+v_{e}^{2}}), capturing the combined sprint time sensitivity to proportional changes in F_{0} and v_{0}; and the force-velocity elasticity ratio {(\mathrm{F}-\mathrm{V}}_{\mathrm{ER}}=F_{e}{\div v}_{e}), indicating which variable dominates the sprint time response. Model simulations showed that F_{e} decreased with rising F_{0} and increased with rising v_{0}, while v_{e} showed the opposite pattern. With increasing sprint distance, F_{e} decreased and v_{e} increased. Given its negligible effect on sprint time, ignoring air resistance yields a conservation law (2F_{e}+v_{e}\equiv 1), indicating that a gain in one elasticity metric necessarily diminishes the other in a fixed proportion. This framework also identifies a valley distance (d_{valley}) at {\mathrm{F}-\mathrm{V}}_{\mathrm{ER}}=2, where {\mathrm{F}-\mathrm{V}}_{\mathrm{EN}} is minimized (\sqrt{0.2}) and sprint time is least responsive to changes in F-V relationship variables. Empirical data confirmed that the two theoretical laws still hold approximately when air resistance is considered. By linking changes in F_{0} and v_{0} to sprint time across different distances, the elasticity framework provides a quantitative basis for estimating the theoretical sprint time response to documented changes in F-V relationship variables.

16
Sensorimotor effects of heatwrap and exercise in acute low back pain: results of a randomised controlled trial

Cote Picard, C.; Desgagnes, A.; Tittley, J.; Mailloux, C.; Perreault, K.; Mercier, C.; Dionne, C. E.; Roy, J.-S.; Masse-Alarie, H.

2026-09-02 rehabilitation medicine and physical therapy 10.64898/2026.08.31.26361841 medRxiv
Top 1%
0.1%
Show abstract

Background: Heatwrap is recommended for acute low back pain (ALBP), and previous research found heatwrap plus exercise more effective than each intervention alone. While recommended by clinical guidelines, their impact on mechanistic outcomes is unknown. This trial aimed to (i) assess immediate and short-term effects of heatwrap alone or combined with exercise, compared with a sham heatwrap, on pain sensitivity, lumbar muscle activity, current pain intensity, and trunk flexion range of motion, and (ii) explore whether changes in pain sensitivity and lumbar muscle activity are associated with changes in clinical symptoms from baseline to 1-week follow-up. Methods: A randomised controlled trial took place at a single research center. Of 315 individuals screened for eligibility, 99 adults with ALBP were recruited and assigned to one of three intervention groups: heatwrap plus exercise (n=34), heatwrap alone (n=33) or sham heatwrap (n=32). Interventions were applied for one hour at the first visit, and immediate effects were measured. Then, interventions were applied for 7 days, and short-term effects were measured at 1-week follow-up. Outcomes included pressure pain threshold, temporal summation of pain, flexion-relaxation ratio, trunk range of motion and current pain intensity. Results: Heatwrap and exercise did not produce greater effects over time than heatwrap alone or a sham heatwrap on all outcomes, and changes in sensorimotor outcomes at one week were not associated with changes in symptoms. Conclusions: Heatwrap and/or exercises did not influence specifically the potential sensorimotor mechanisms tested in individuals with ALBP. Trial registration: ClinicalTrials.gov; registration number: NCT03986047

17
Low-Density Lipoprotein Modulates Plasma Fibrin Network Architecture and Impairs Fibrinolysis

Nameny, A.; DeSmet, A.; Cai, C.; R. Baker, S.; Bonin, K.; E. Hudson, N.; E. Bannish, B.; Guthold, M.

2026-09-01 biophysics 10.64898/2026.08.31.748310 medRxiv
Top 1%
0.1%
Show abstract

Low-density lipoprotein (LDL) is a major atherogenic lipoprotein, yet its potential to directly modify the fibrin scaffold of blood clots is incompletely understood. Here, we investigated how LDL alters plasma fibrin network architecture and internal fibrinolysis across defined fibrinogen/thrombin conditions. Pooled normal human plasma was supplemented with LDL and clotted with controlled concentrations of fibrinogen and thrombin. Fibrin architecture was visualized by confocal microscopy and quantified by pore-size analysis; clot formation and lysis were monitored turbidimetrically in the presence of tissue plasminogen activator (tPA). Increasing LDL produced a pronounced reduction in fibrin-network pore size across the tested fibrinogen/thrombin conditions. The LDL dependence of pore diameter was well described by a power-law relationship, D_pore=(6.54 +/- 0.11)[LDL]^(-0.12 +/- 0.02) , (R^2 = 0.90), with a significant negative LDL exponent (p = 4 x 10^5). Increasing LDL also prolonged clot lysis time and altered turbidity kinetics. These findings extend epidemiologic and clinical associations between ApoB-containing lipoproteins and hypofibrinolytic clot phenotypes by demonstrating, in a controlled plasma system, that LDL itself can modify fibrin network architecture and fibrinolytic susceptibility. The results support a structure-function role for LDL within the fibrin biomaterial and motivate direct tests of LDL incorporation, protofibril packing, fibrinolytic-protein binding, and single-fiber mechanics.

18
Inflammation Beyond the Disc: Circulating Inflammatory Biomarkers in Lumbar Disc Herniation and Degeneration--A Case-Control Study

Withanage, N. D.; Perera, S.; Athiththan, L.

2026-08-31 orthopedics 10.64898/2026.08.28.26361607 medRxiv
Top 1%
0.1%
Show abstract

Background: Lumbar disc herniation, with or without concomitant disc degeneration, is a major cause of lumbar radiculopathy and low back pain, which also a key public musculoskeletal disorder without an exact pathophysiology. Studies have suggested that inflammatory cells and biochemical markers of inflammation also play an important role in lumbar radiculopathy in addition to nerve compression. The aim of the present study was to assess the association of selected circulatory inflammatory markers (CRP, hs-CRP and E-selectin) in patients with lumbar disc herniation without radiological degeneration (LDH) and lumbar disc herniation with radiological degeneration (LDHD). Materials & methods: This case-control study included 208 participants, comprising 104 patients with lumbar disc pathology and 104 controls. Patients were further stratified into LDH (n=67) and LDHD (n=37). Serum CRP, hs-CRP and E-selectin concentrations were measured. Results: Among the patients, 35.6 % presented with LDHD while 64.4 % had only LDH. Significantly increased median hs-CRP (p<0.001) and CRP (p<0.001) were observed in patients groups compared to controls, while CRP showing a consistent independent association across the combined disease (OR=1.68, 95% CI=1.33-2.14, p<0.001), LDHD (OR=1.62, 95% CI=1.16-2.20, p=0.005) and LDH (OR=1.69, 95% CI=1.30-2.20, p<0.001) multivariable models. No significant difference was observed in serum E-selectin between the study groups. Multivariable models incorporating inflammatory and clinical variables demonstrated substantially greater discriminatory performance than individual biomarkers alone. Conclusion: Elevated circulating CRP and hs-CRP concentrations were associated with lumbar disc pathology, with CRP showing a consistent independent association across the combined disease, LDH and LDHD multivariable models, whereas E-selectin showed no significant association. Multivariable models incorporating inflammatory and clinical variables demonstrated greater discriminatory performance than individual biomarkers. These findings support a potential systemic inflammatory component in lumbar disc pathology, although the cross-sectional nature of the measurements does not establish causality or a local inflammatory response within the disc.

19
Constraining Palaeogeography and Palaeotides for the Cambrian using cnidarian medusae

Byrne, H. A. M.; Hartley, M. E. H.; Perez, I.; Scotese, C. R.; Lunt, D. J.; Valdes, P. J.; Green, J. A. M.

2026-09-01 paleontology 10.64898/2026.08.27.747545 medRxiv
Top 2%
0.1%
Show abstract

The ocean tides influence key Earth system processes at a range of spatial and temporal scales. It is known that the geometry of ocean basins is the leading controller of tidal energetics, so well-constrained palaeogeographic reconstructions and tidal properties for Earths past are imperative when investigating other Earth system processes. Here, we present a novel way to constrain both deep-time tidal model results and reconstructions, by combining palaeoecology with sedimentology. We compare new palaeo-tidal model simulations for the Cambrian period, significant for the early origin and radiation of major animal fauna, to tidal proxies. One of the most abundant soft-bodied organisms preserved during this time are cnidarian medusae (jellyfish). A total of 17 cnidarian medusae localities were obtained through the literature, which had an adequate global distribution and occurred at regular intervals throughout the period of study. In some locations there were also estimates of palaeo-tidal range. Our results show a good agreement between the simulations and proxy data. In the few locations where there is disagreement, it is proposed that the palaeogeographic reconstructions are missing details, e.g., island chains, and our results allow for the palaeogeographic reconstructions to be improved. The proxy method presented is promising and can be applied to other time-periods with different marine fossils, particularly at evolutionary and extinction periods where the marginal marine environment is of importance.

20
Patterns and Outcomes of Occupational Injuries in Emergency Departments at Nigerian Hydropower Plant Hospitals: A Retrospective Study

Ojo, J. O.

2026-09-04 emergency medicine 10.64898/2026.08.31.26361543 medRxiv
Top 2%
0.1%
Show abstract

Occupational injuries remain a cause of preventable morbidity and death, but evidence from emergency departments in Nigeria is limited. This retrospective study described occupational injuries treated at two hydropower plant hospitals between May 2020 and December 2022. Records of 120 patients were reviewed using a standardized abstraction form. Data were summarized using frequencies and percentages, and associations were assessed using chi-square tests. Vehicular crashes were the leading cause of injury (50.0%), lacerations were the most frequent injury type (39.2%), and the head/face was the most commonly affected single site (30.0%). Most patients were discharged (85.0%); 12.5% were transferred and 3.3% died. Serious injuries accounted for 40.8% of cases. Injury type was associated with discharge and injury severity, while injury site was associated with discharge and transfer. These findings support stronger workplace prevention, timely emergency assessment, and clearer referral pathways for injured workers.